Q1: What causes poor separation performance (e.g., cloudy supernatant, high moisture content in the solid phase), and how can this be resolved ?

Key causes and solutions:

1. Rotational speed below setpoint (VFD fault or speed sensor failure): Inspect the electrical control system and calibrate speed parameters;

2. Filter screen/cloth clogged, damaged, or incorrectly selected: Clean or replace the filter medium and re-select based on material particle size;

3. Excessive or uneven feed rate: Reduce feed speed and maintain a steady flow;

4. Fluctuations in material properties (e.g., increased viscosity, finer particles): Increase rotational speed and/or extend separation time;

5. Imbalance due to material buildup on the inner drum wall: Shut down the machine and clear out residual material.

Q2: What causes the centrifuge to vibrate violently or the machine body to shake severely, and how should this be addressed?

Common causes:

1. Uneven material distribution or accumulation of solid residue inside the drum;

2. Bearing wear, aging, or lubrication failure;

3. Loose anchor bolts or improper leveling during installation;

4. Deformation of the drum or main shaft, or imbalance due to component wear;

5. Off-center loading or excessive fluctuations in material concentration.

Solutions: Immediately shut down the machine, clear residual material from the drum, tighten anchor bolts and re-level the equipment, replace worn bearings and replenish lubricant, inspect drive components, and optimize feed uniformity.

Start Your Dream Project Solution Now! We Provide You Complete Turnkey Solution!

Quick Links

Products

Contact Us

 +86-159-9546-3675(Jay Wang)
    +86-139-1329-1927
 +8615995463675
     +8613913291927
 sales@jgdcentrifuge.com
     info@jgdcentrifuge.com
 No.2, Lefeng Road, Leyu Town, Zhangjiagang City, Jiangsu Province, China.
Copyright © 2026 JGD Centrifuge. All Rights Reserved. Sitemap | Privacy Policy